GROUNDING / EARTH TEST 0-5KV
Dust and drip proof.(designed to IEC 60529 IP54)
• In addition to the facility for precision measurement, test leads for simplified two wire easuring system also supplied as standard accessories.
(unit can be hung from the neck for simplified measurement)
• Designed to meet IEC 61010-1 safety standard.
• Capable of measuring earth voltage.
• Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.
• Small and lightweight. Shock resistant new case material.
• 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
Measurement ranges Earth Resistance: 0 - 20Ω/0 - 200Ω/0 - 2000Ω
Earth Voltage [50,60Hz]: 0 - 200V AC Accuracy Earth Resistance: ±2%rdg±0.1Ω (20Ωrange)
±2%rdg±3dgt (200Ω/2000Ωrange)
Earth Voltage: ±1%rdg±4dgt Overload protection Earth Resistance: 280V AC for 10 seconds
across 2 of the 3 terminals
Earth Voltage: 300V AC for 1 minute Applicable standards IEC 60529 IP54 Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2, IEC 61557 Power source R6 (AA) (1.5V) × 6 Dimensions 105(L) × 158(W) × 70(D)mm Weight 550g approx. Included Accessories 7095A (Earth resistance test leads) × 1set
(red-20m, yellow-10m, green-5m)
8032 (Auxiliary earth spikes) × 1set
7127A (Simplified measurement probe) × 1set
R6 (AA) × 6
9121 (Shoulder strap)
Instruction Manual
Carrying case : 9084(Carrying case[Soft]:4105A only)
: 9165(Carrying case[Hard]:4105A-H only) Optional Accessories 7100A (Precision measurement cord set)
PT. CAHAYA MANDIRI ELEKTRIK
PT.Cahaya Mandiri Elektrik bergerak di bidang Elektrikal dengan spesialisasi di :
- Testing dan Commissioning
- Maintenance Switchgear & Transformer
- Mekanikal – Elektrikal
Kami melayani maintenance / inspeksi transformer :
- Standard Test : Tan Delta / power factor, Bushing, SFRA, Trafo Turn Ratio, DC Resistance, Index Polarity, BDV Oil test, Vector Group, Winding Resistance, Impedance Test, Oil purification, Water content / oil sampling test, Viscosity, Thermalgraph, Flash Point.
- Special Test :
Soak test, Close Open Circuit, Induce Test, Partial Discharge, Harmonic Test
Menyewakan / Rental Alat Uji Electrical Omicron Brand, Megger, dll.
1. Primary Injection - Omicron CPC 100
2. Secondary Injection - Omicron CMC 356, Vebko AMT 105
3. Contact Resistance - Vebko AMT 105
4. Hipot AC/DC - HIPOTECH, Phenix
5. Current Transformer Analyzer - Omicron
6. Circuit Breaker Analyzer - Vebko AMT 105, Megger Egil
7. Insulation Tester - Kyoritsu
8. SF 6 Analyzer - DILO
CP : Ronnie / Cinthya
+62 852-1991-2158 (Whatsapp)
TESTING INSTRUMENT